Description

The automatic dT100 control for ventilation and temperature tasks was developed for flexible use in wineries. The OFF – MANUAL – NIGHT AIR – TIME operating modes can be freely selected using buttons in the front of the controller. The system directly actuates motorised closure flaps and fans. A programmed time regime ensures that the closure flap is always opened before the fan starts up. Deactivation is achieved in reverse order. The closure flap only closes with a time delay after the fan stops. In the TIME operating mode, ventilation in the case of an activated time window is controlled without regard for the indoor and outdoor temperature (e.g. for regular air renewal, tartaric stabilisation, etc.). In addition, a clock signal with defined activation and deactivation times can be defined in TIME operating mode within the time window. In the NIGHT AIR operating mode, ventilation is actuated in the programmed time window (up to 4 time windows) if the outside temperature is at least 1 °C (configurable value) lower at the starting point than the indoor temperature.

Features

  • AC 230V/50Hz
  • Max. output of blowers + flaps 2/3, 6/6 kVA
  • Protection rating (EN60529): IP65
  • Operating mode selection OFF – MANUAL – NIGHT AIR – TIME
  • Digital timer switch with power reserve, freely programmable
  • 4 independent switching times each in night air and time mode
  • Release input for humidistat control
  • Release input for forced activation through CO2 monitor
  • Digital differential temperature controller with PT100-3L probe inputs (for greater distances)
  • Digital display for indoor/outdoor temperature and time
  • Alarm output (relay) and alarm status display
  • Delayed fan start-up after opening of flaps
  • Delayed closure of flaps after fan deactivation
  • ABS housing with transparent door: L x H x D=190 x 200 x 110mm
  • Accessories: Fastening clips, cable glands